Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 64
Filter
1.
RGO (Porto Alegre) ; 71: e20230007, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1431164

ABSTRACT

ABSTRACT Objective: To evaluate the dimensional change of edentulous models made of high density laboratory silicones at different storagetimes. Methods: A metallic master model simulating an edentulous maxilla was used. The model had projections of 1.8 cm located in the regions of canines (A and B) and molars (C and D) allowing the linear measurement of distances AB, BC, CD, DA, AC and BD. A laboratory silicone mold was made for duplication of master model in the following materials (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 and G4: Gypsum type III (control). The samples were photographed and measured using a software (Image J) at times T1 (baseline) and T2 (after one week of models fabrication). The data were statistically analyzed using Kruskal- Wallis and Dun non-parametric tests (α = 0.05). Results: The storage time influenced the behavior of the materials evaluated. All groups presented dimensional changes in both times and the group Tit95 presented the best results. Only Zet85 group showed a different behavior related to the region of the model. Conclusions: The high density laboratory silicones showed satisfactory results when compared to the gypsum group. Tit95 was the most stable material and it can be recommended as an edentulous model for total protheses.


RESUMO Objetivo: Avaliar a alteração dimensional de modelos edêntulos fabricados em silicone laboratorial de alta densidade em diferentes tempos de armazenagem. Métodos: Um modelo mestre metálico simulando uma maxila edêntula foi utilizado. O modelo possuía projeções oclusais de 1,8 cm localizadas nas regiões de caninos (A e B) e molares (C e D), permitindo a mensuração das distâncias lineares AB, BC, CD, DA, AC e BD. Um molde foi fabricado em silicone laboratorial para duplicação do modelo mestre com os seguintes materiais (n = 10): G1: Zetalabor 85, G2: Titanium 95, G3: Platinum 95 e G4: Gesso tipo III (controle). As amostras foram fotografadas e mensuradas com auxílio de um software (Image J) nos tempos T1 (baseline) e T2 (após uma semana de confecção). Os dados obtidos foram avaliados estatisticamente utilizando os testes não paramétricos de Kruskal- Wallis e Dunn (α = 0.05). Resultados: O tempo de armazenagem influenciou o comportamento dos materiais avaliados. Todos os grupos apresentaram alterações dimensionais em ambos os temos de avaliação e o G2 apresentou os melhores resultados. Apenas o grupo G1 mostrou alteração dimensional dependente da região mensurada. Conclusão: Silicones laboratoriais de alta densidade mostraram resultados satisfatórias de alteração dimensional quando comparados ao gesso tipo III. O material Titanium 95foi o mais estável e pode ser recomendado como alternativa para a confecção de modelos edêntulos.

2.
Rev. bras. cir. plást ; 37(4): 400-405, out.dez.2022. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1413136

ABSTRACT

Introdução: A descrição do linfoma anaplásico de células T e o recente aumento das cirurgias de explante resultou na elevação do número de exames anatomopatológicos nas cirurgias de retirada de implantes mamários de silicone. O objetivo desta pesquisa é analisar a qualidade e quantidade de dados contidos na requisição do exame histopatológico. Métodos: Foram estudados 251 casos. Os seguintes dados foram analisados: sexo, idade, localização anatômica e espacial, lateralidade, história clínica, sinais e sintomas, quimioterapia e radioterapia prévia, hipótese diagnóstica, cirurgias prévias, tipo e marca do implante, exames de imagem prévios e número e características dos espécimes enviados. Resultados: A idade média foi de 43 anos. A lateralidade não foi mencionada em 16 (0,84%). A localização anatômica foi citada em 15 casos. O tipo de cirurgia foi mencionado por 40 (15,94%). O número de contêineres variou de 1 a 5, com mediana de 2. A cápsula foi enviada em 242 casos, em 161 de forma isolada, tecido mamário em conjunto com cápsula em 27, tecido mamário e cápsula em contêineres diferentes em 54 casos. A história clínica foi incluída em 19,12%, sinais e sintomas em 13,94%, em que a contratura foi o único termo inserido em 64. Em 27 requisições foi citado linfoma. Em 15 pacientes a presença de seroma foi referida e destes nove foram enviados. O tipo e marca do implante não foi citado. Conclusão: Os dados são escassos. Recomenda-se a criação de protocolos na retirada da cápsula e tecido adjacente, incluindo a orientação anatômica e espacial.


Introduction: The description of the Anaplastic Large Cell Lymphoma and the explantation surgery resulted in an increase of histopathological exams in breast implant removing surgery. Methods: 251 pathology requests were studied. The following data from the medical requests were analyzed: gender, age, type of surgery, number of specimens containers sent, laterality, anatomical and spatial location, clinical history, signs and symptoms, previous radiotherapy, previous chemotherapy, diagnostic hypothesis, previous surgeries, and reference to previous breast exams. Results: The mean age was 43 years old. Laterality was not mentioned in 16 requests. The surgery performed was mentioned in 15.94% requests. The number of containers varies from 1 to 5, with a median of 2. The containers include capsules in 242 cases, 161 as isolated capsule, 27 mammary tissue, and capsule in the same specimen, 54 mammary tissues sent in a separate container, anatomical and spatial location was mentioned in 6.33% cases. The detailed clinical data was included in 19.12%, signs and symptoms 13.94%, contracture as the only item mention in 64 of them. In 27 requests, lymphoma evaluation was requested. 15 included seroma and from nine of those, liquid was sent with a request for immunohistochemical and cytology analysis. None of the requests had any data on implant type or brand. Conclusion: The amount of information contained in the medical request forms is minimal. The authors recommend the need for a protocol to standardize the surgical removal of the capsule and the adjacent mammary tissue. Surgical specimens should be spatially oriented.

3.
Rev. bras. cir. plást ; 37(4): 485-493, out.dez.2022. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1413224

ABSTRACT

A síndrome autoimune induzida por adjuvantes (ASIA) e seus critérios diagnósticos foram descritos por Shoenfeld em 2011, relacionando sintomas de autoimunidade a adjuvantes, como o silicone, presente em próteses mamárias. Essa revisão sistemática objetivou reunir dados da literatura sobre a sintomatologia, a incidência e os tratamentos propostos para ASIA causada por implantes mamários de silicone (IMS). Foram realizadas pesquisas nas bases de dados PubMed, LILACS, Embase e Cochrane, utilizando os descritores "Autoimmune Syndrome Induced by Adjuvants", "Breast implant" e "Silicone Implant Incompatibility Syndrome". A estratégia de busca gerou 95 artigos, dos quais 20 foram incluídos na revisão. São as três as principais teorias sugeridas pelos autores para explicar o desenvolvimento da síndrome: predisposição genética, silicone bleeding e a formação de uma cápsula periprótese. As manifestações clínicas mais frequentemente descritas incluem fadiga crônica, artralgia, mialgia, distúrbios cognitivos e do sono. Não há consenso sobre os achados laboratoriais e os fatores de risco associados, além disso, estudos recentes propõem a ampliação dos critérios diagnósticos inicialmente descritos. O tratamento adequado permanece controverso, envolvendo desde o uso de medicações até o explante da prótese. Apesar dos artigos revisados sugerirem a existência da ASIA relacionada aos IMS, sua fisiopatologia precisa é desconhecida, os sintomas relatados são inespecíficos e o tempo entre a exposição e o surgimento das manifestações é incerto. Por meio dessa revisão sistemática, conclui-se que, até o presente momento, não existem evidências científicas suficientes para estabelecer a causalidade do desenvolvimento da síndrome autoimune induzida por adjuvantes decorrente de implantes mamários de silicone.


Adjuvant-induced autoimmune syndrome (ASIA) and its diagnostic criteria were described by Shoenfeld in 2011, relating symptoms of autoimmunity to adjuvants, such as silicone, present in breast implants. This systematic review aimed to gather data from the literature on symptomatology, incidence and proposed treatments for ASIA caused by silicone breast implants (SBI). Searches were carried out in PubMed, LILACS, Embase and Cochrane databases, using the descriptors "Autoimmune Syndrome Induced by Adjuvants," "Breast implant," and "Silicone Implant Incompatibility Syndrome." The search strategy generated 95 articles, of which 20 were included in the review. The authors suggest three main theories to explain the development of the syndrome: genetic predisposition, silicone bleeding and the formation of a periprosthetic capsule. The most frequently described clinical manifestations include chronic fatigue, arthralgia, myalgia, and cognitive and sleep disorders. There is no consensus on laboratory findings and associated risk factors; recent studies propose expanding the diagnostic criteria initially described. Adequate treatment remains controversial, ranging from medications to prosthesis explantation. Although the reviewed articles suggest the existence of ASIA related to SBI, its precise pathophysiology is unknown, the symptoms reported are nonspecific, and the time between exposure and the onset of manifestations is uncertain. This systematic review concludes that, to date, there is not enough scientific evidence to establish the causality of the development of adjuvant-induced autoimmune syndrome resulting from silicone breast implants.

4.
Braz. j. oral sci ; 21: e225757, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1366215

ABSTRACT

Aim: This study aimed to evaluate the effect of frozen storage on the physical properties of a silicone-based test food material, highly used to evaluate the masticatory performance in research settings. Methods: A total of 1,666 silicone cubes of Optosil Comfort® with 5.6-mm edges were shaped and stored at -18°C. The cubes were subsequently tested for flexural strength (maximum force, displacement, stress, and strain) before breaking (n = 136), changes in weight and size (n = 170), and masticatory performance (n = 1360) at eight timepoints: immediately after cube preparation (baseline, no freezing), and 1, 2, 3 and 4 weeks, and 2, 4 and 6 months after frozen storage. The cubes were thawed 8 h before each assessment. Results: The maximum force, stress, maximum displacement, and deformation values for the cubes were not affected by freezing (P > 0.05). At all of the time points, the cubes exhibited similar weight (P = 0.366) and size (identical values). The masticatory performance for the cubes also showed no differences from baseline through 6 months (P = 0.061). Conclusion: Freezing Optosil Comfort® silicone cubes did not alter the physical and mechanical properties of the material, being suitable to optimize the assessment of masticatory parameters for research purposes


Subject(s)
Humans , Male , Adult , Silicone Elastomers , Materials Testing/methods , Freezing , Flexural Strength , Mastication , Time Factors
5.
Rev. bras. cir. plást ; 37(2): 154-162, abr.jun.2022. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1379738

ABSTRACT

Introdução: Após a colocação de implantes mamários de silicone, algumas pacientes apresentam sintomas descritos como doença do implante mamário e buscam a cirurgia de explante. O objetivo deste estudo é analisar o histórico de sintomas e verificar as impressões dos pacientes submetidos ao explante mamário em três momentos distintos: antes de colocar os implantes mamários, enquanto estavam com os implantes e após a cirurgia de explante. Métodos: Essa pesquisa foi delineada como um estudo observacional longitudinal multicêntrico utilizando um questionário on-line de participação voluntária enviado por e-mail. Resultados: Foram analisados 156 pacientes, 84% apresentavam três ou mais sintomas e 66,1% destes obtiveram melhora de sua sintomatologia após o explante (p<0,001). Antes da colocação de silicone, a mediana de autossatisfação corporal era de 7, enquanto estavam com os implantes a mediana tornou-se 9 e após a cirurgia de explante a mediana se manteve em 9 (p<0,001). Grupos de apoio em redes sociais auxiliaram na decisão de fazer o explante em 87,2% das pacientes. Conclusão: Pacientes que têm sintomas após colocarem silicone apresentam melhora com a retirada dos implantes mamários. A autossatisfação corporal aumenta com a colocação de implantes mamários e permanece elevada após a retirada destes. Pacientes que fazem a cirurgia do explante costumam estar arrependidas de terem colocado silicone, muito satisfeitas com a decisão de removêlos e igualmente satisfeitas com o resultado da cirurgia de explante mamário. Grupos de apoio em redes sociais foram importantes na tomada de decisão destas pacientes.


Introduction: Following silicone breast implant placement, some patients present symptoms described as breast implant illness and seek explant surgery. This study aims to analyze the historical symptoms and ascertain breast explant patients' impressions at three different times: before breast implant placement while having the implants, and after the explant surgery. Methods: This survey was designed as a multicenter longitudinal observational study using an online voluntary participation questionnaire sent by e-mail. Results: 156 patients were analyzed, 84% had three or more symptoms, and 66.1% improved their symptoms after the explant (p<0.001). Before the placement of silicone, the median self-body satisfaction was 7, while with the implants, the median became 9, and after the explant surgery, the median remained up to 9 (p<0.001). Support groups on social networks helped in the decision to explant in 87.2% of the patients. Conclusion: Patients presenting symptoms after silicone placement show improvement with breast implant removal. Body self-satisfaction increases with the placement of breast implants and remains increased after their removal. Patients who undergo the explant surgery usually regret having implanted silicone; they are very satisfied with the decision to remove them and equally satisfied with the result of the breast explant surgery. Support groups on social networks were important in the decision-making of these patients.

6.
Rev. bras. cir. plást ; 37(1): 89-93, jan.mar.2022. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1368246

ABSTRACT

Apesar dos mais de 60 anos de história, dezenas de estudos e grandes amostras populacionais, nos últimos anos diversos pacientes têm retornado ao consultório do cirurgião plástico. Apresentam dúvidas a respeito do silicone, algumas devido aos relatos recentes de BIA-ALCL (Anaplastic Large Cell Lymphoma), mas a grande maioria pela possibilidade de sintomas sistêmicos relacionados aos implantes e que despertam o desejo da sua remoção. Procedimento conhecido como explante. Este fenômeno, cujas dúvidas são inúmeras e as respostas mínimas, é conhecido na literatura mundial como Breast Implant Illness (BII). Na Internet e redes sociais, centenas de sinais e sintomas têm sido relacionados às próteses de silicone, usualmente inespecíficos. Os sintomas mais comuns referidos pelas pacientes são fadiga crônica, artralgia, confusão mental, mialgia, perda de memória, dificuldade de concentração e olhos secos. Até o momento, não existem testes diagnósticos para BII, nenhum método baseado em evidência científica para diferenciá-la de outras condições e há muito pouco conhecimento a respeito do seu início, curso, fatores de risco, causas e manejo adequado. A opção pela retirada dos implantes vem crescendo vertiginosamente nos últimos anos, sendo uma das dez cirurgias mais realizadas nos Estados Unidos no ano passado. A literatura mostra taxas de melhora dos sintomas variáveis após o explante e as pacientes mostram-se, via de regra, satisfeitas com seu resultado estético e apresentam níveis de ansiedade e estresse menores após o procedimento. São necessários estudos prospectivos, randomizados bem desenhados correlacionando períodos distintos das pacientes, desde o pré-operatório do implante até o pós-explante.


Despite more than 60 years of history, numerous studies and large population samples, in recent years, several patients have returned to the plastic surgeons office. They have doubts about the silicone, some due to the recent reports of BIAALCL, but the vast majority due to the possibility of systemic symptoms related to the implants and which arouse the desire for its removal. Procedure known as explant. This phenomenon, whose doubts are numerous and the responses are minimal, is known in the world literature as Breast Implant Illness (BII). On the Internet and social networks, hundreds of signs and symptoms have been related to silicone implants, usually nonspecific. The most common symptoms reported by patients are chronic fatigue, arthralgia, mental confusion, myalgia, memory loss, difficulty concentrating and dry eyes. So far, there are no diagnostic tests for BII, no method based on scientific evidence to differentiate it from other conditions, and there is very little knowledge about its onset, course, risk factors, causes and proper management. The option for removing the implants has been growing dramatically in recent years, being one of the ten most performed surgeries in the United States last year. The literature shows variable improvement rates after the explantation and the patients are, as a rule, satisfied with their aesthetic result and have lower levels of anxiety and stress after the procedure. Prospective, well-designed randomized studies correlating different periods are necessary, from the preoperative period of the implant until after the explantation.

7.
Rev. bras. cir. plást ; 36(3): 358-365, jul.-set. 2021. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1365563

ABSTRACT

RESUMO Introdução: Os procedimentos estéticos na região glútea têm ganhado evidência nas últimas décadas, com aumento da procura e aparecimento de novas técnicas. Somado ao desenvolvimento e maior facilidade de acesso aos métodos de imagem, assim como a crescente judicialização da medicina, tornam-se cada vez mais frequentes os exames de imagem nos pacientes submetidos a gluteoplastia, com destaque atualmente para a avaliação por ressonância magnética desta região. Dessa forma, a imagem entra cada vez mais na prática clínica diária do cirurgião plástico, requerendo do mesmo conhecimentos sobre conceitos básicos em relação à solicitação e interpretação dos exames. Neste artigo, revisamos aspectos de imagem por ressonância magnética de procedimentos estéticos da região glútea, bem como suas complicações. O objetivo é ilustrar através de estudos de ressonância magnética os achados habituais nos procedimentos de gluteoplastia, bem como algumas de suas complicações, além de propor um protocolo de exame por ressonância magnética da região. Foram selecionados selecionados casos ilustrativos de pacientes que se submeteram a procedimentos de gluteoplastia, sejam eles aprovados, off-label ou mesmo ilícitos, e que fizeram estudo de ressonância magnética em nosso serviço. Foi realizada ainda revisão bibliográfica sobre o tema.


ABSTRACT Introduction: Aesthetic procedures in the gluteal region are increasingly in evidence in recent decades with the augment in demand and the emergence of new techniques. This fact, coupled with the development and easier access to imaging methods and the increasing judicialization of medicine, makes imaging exams more frequent in patients undergoing gluteoplasty, with an emphasis currently on magnetic resonance imaging in this region. Thus, the image increasingly enters the plastic surgeon's daily clinical practice, requiring knowledge of basic concepts regarding the request and interpretation of the exams. In this article, we reviewed aspects of magnetic resonance imaging of aesthetic procedures in the gluteal region and their complications. The objective is to, through magnetic resonance studies, the usual findings in gluteoplasty procedures, as well as some of their complications, in addition to proposing an examination protocol for magnetic resonance imaging in the region. Illustrative cases of patients who underwent gluteoplasty procedures, whether approved, off-label or even illicit, were selected, in which we conducted a magnetic resonance study in our service. A bibliographic review was also done on the topic.

8.
Med. UIS ; 33(3): 49-58, sep.-dic. 2020. graf
Article in Spanish | LILACS | ID: biblio-1360576

ABSTRACT

Resumen Las quemaduras secundarias a agresión física con intención de desfigurar, torturar o incluso asesinar, se han convertido en un motivo de consulta común en el siglo XXI, siendo Bangladesh el país con la más alta incidencia en el mundo. Colombia es uno de los países con mayor incidencia a nivel de Latinoamérica. La mayoría de las lesiones ocurre en áreas expuestas como el rostro y se acompaña de graves secuelas físicas, estéticas y funcionales. Se realiza la presentación de caso de una paciente de 35 años con quemaduras de tercer grado en región frontal, periocular, malar bilateral, nasal, labial superior y pabellón auricular derecho, manejada con injertos de piel, quien posteriormente desarrolla cicatriz hipertrófica. Se describe el tratamiento con máscara termoplástica elaborada por los profesionales tratantes, con cubierta interna de silicona, fabricada sobre molde a medida y ajustada con bandas elásticas; integrando en un único dispositivo removible, cómodo y de bajo costo, diferentes alternativas terapéuticas que logran modular efectivamente el proceso de cicatrización y por su simplicidad favorecen la adherencia al tratamiento, la cual es indispensable para obtener resultados satisfactorios. MED.UIS.2020;33(3): 49-58


Abstract Burns secondary to physical aggression with the intention of disfiguring, torturing or even murdering, have become a common reason for consultation in the 21st century, with Bangladesh being the country with the highest incidence in the world. Colombia is one of the countries with the highest incidence in Latin America. Most injuries occur in exposed areas such as the face and are accompanied by serious physical, aesthetic and functional sequelae. We present the case of a 35-year-old patient with third degree burns in the frontal, periocular, bilateral malar, nasal, upper labial and right ear region, managed with skin grafts, who later developed a hypertrophic scar. The treatment with a thermoplastic mask made by the treating professionals is described, with an internal silicone cover, made on a custom mold and adjusted with elastic bands; integrating in a single removable, comfortable and low-cost device, different therapeutic alternatives that manage to effectively modulate the healing process and, due to their simplicity, favor adherence to treatment, which is essential to obtain satisfactory results. MED.UIS.2020;33(3): 49-58


Subject(s)
Humans , Cicatrix, Hypertrophic , Pressure , Silicone Elastomers , Wound Healing , Skin Transplantation
9.
Rev. bras. cir. plást ; 35(4): 505-513, out.dez.2020. ilus
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1367960

ABSTRACT

O autor conviveu com implantes mamários e relata a história da evolução em seus 45 anos de experiência. Aponta os pontos principais dessa evolução, as coincidências e as complicações no transcorrer do tempo, e propõe ao final acontecimentos possíveis no futuro.


The author lived with breast implants and tells the story of evolution in his 45 years of experience. It points out the main points of this evolution, the coincidences, and complications over time, and proposes possible future events in the end.

10.
Rev. bras. cir. plást ; 35(3): 340-345, jul.-sep. 2020. ilus, tab
Article in English, Portuguese | LILACS-Express | LILACS | ID: biblio-1128071

ABSTRACT

A assimetria mamária é um diagnóstico prevalente com diversas modalidades cirúrgicas para seu tratamento. O correto diagnóstico, levando-se em conta os sistemas de classificação existentes é imperativo para que os melhores resultados sejam alcançados. Através de revisão da literatura foram levantadas as principais e mais aceitas propostas de classificação e tratamento das assimetrias mamárias. Estas classificações disponíveis datam da década de 60 e 70 e carecem de atualização para o contexto clínico atual. Após ampla revisão da literatura foi proposta uma classificação mais simplificada e reprodutível, levando-se em conta as assimetrias mais frequentes nos consultórios de cirurgia plástica estética, com seus respectivos guias de tratamento. Cinco grupos foram criados: 1 - mamas hipotróficas com assimetria de volume; 2 - hipotrofia com assimetria de volume e contorno; 3 - mamas normotróficas, ptóticas e sem desejo de aumento do volume; 4 - mamas normotróficas, ptóticas e com desejo de aumento do volume final; 5 - mamas assimétricas e hipertróficas. Baseado nos achados clínicos, foi criado um algoritmo de tratamento para cada subtipo de assimetria, incluindo neste arsenal, próteses mamárias de volumes diferentes, mastopexias, mamoplastia redutoras, além da lipoenxertia. Importante ressaltar que a assimetria mamária é a regra e não a exceção, entretanto, é motivo de insatisfação das pacientes e um desafio para o cirurgião plástico.


Breast asymmetry is a prevalent diagnosis that has several surgical modalities for its treatment. The correct diagnosis, taking into account the existing classification systems, is imperative for achieving the best results. The leading and most accepted proposals for the classification and treatment of breast asymmetries were raised through the literature review. These available classifications date from the 60s and 70s and need to be updated to the current clinical context. A more simplified and reproducible classification was proposed after a comprehensive literature review, considering the most frequent asymmetries in aesthetic plastic surgery offices, with their respective treatment guides. Five groups were created: 1 - hypotrophic breasts with volume asymmetry; 2 - hypotrophy with volume and contour asymmetry; 3 - normotrophic, ptotic breasts and with no desire to increase the volume; 4 - normotrophic, ptotic breasts and with a desire to increase the final volume; 5 - asymmetric and hypertrophic breasts. Based on the clinical findings, a treatment algorithm was created for each subtype of asymmetry, including in this arsenal, breast implants of different volumes, mastopexies, reduction mammoplasty, and fat grafting. It is important to emphasize that breast asymmetry is the rule and not the exception, therefore, it is a reason for patient dissatisfaction and a challenge for the plastic surgeon.

11.
Acta cir. bras ; 35(4): e202000407, 2020. tab, graf
Article in English | LILACS | ID: biblio-1130635

ABSTRACT

Abstract Purpose To evaluate whether silicone foam implants have a different evolution pattern compared to conventional texture implants. Methods Fifty-eight female patients underwent surgery. They were divided into two groups (silicone foam - Lifesil® - and microtexturized silicone - Lifesil®). The evolution was analyzed in postoperative consultations, with physical examination, photographic documentation and filling in a satisfaction questionnaire, in the postoperative period of one month, four months, one year and then annually, up to a maximum of 3 years of follow-up. Results There were no statistically significant differences in presence of rippling, stretch marks, breast ptosis, capsular contracture and quality of scars. There was a higher rate of patients who were very satisfied with the outcome 360 days after surgery in the group receiving silicone foam implants (p = 0.036). Conclusion In short time, silicone foam envelope implants proved to be as reliable as textured silicone envelope implants, making them an option for augmentation mammoplasty.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Silicone Elastomers/therapeutic use , Breast Implantation/methods , Postoperative Complications , Time Factors , Breast/drug effects , Prospective Studies , Reproducibility of Results , Risk Factors , Foreign-Body Reaction/pathology , Treatment Outcome , Patient Satisfaction , Breast Implants/adverse effects , Breast Implantation/adverse effects , Middle Aged
12.
ROBRAC ; 28(85): 62-67, abr./jun. 2019. Ilus, Tab
Article in Portuguese | LILACS | ID: biblio-1049234

ABSTRACT

Objetivo: Comparar diferentes técnicas de moldagem com silicone de adição, quanto à precisão e fidelidade da cópia através de medidas manuais e sobreposição em CAD/CAM. Material e método: Foram realizadas 4 moldagens com silicone de adição de um mesmo modelo nas seguintes técnicas: T1 ­ dois passos com recorte; T2 ­ dois passos com alívio de filme PVC; T3 ­ dois passos sem alívio e T4 - simultânea. A fidelidade das 4 técnicas de moldagem foi avaliada por meio de mensurações de 5 dimensões nos modelos de gesso vazados em cada um dos moldes obtidos. Outra forma de análise foi a sobreposição de imagens no CAD/CAM, com a finalidade de verificar se há semelhanças ou diferenças dimensionais entre o modelo piloto e as amostras. As medidas obtidas foram submetidas ao teste ANOVA com comparações múltiplas pelo teste de Tukey (α=0,05). Resultados: De acordo com as mensurações, a técnica que apresentou maior discordância do modelo piloto foi a T4, não havendo diferença entre as outras técnicas. Na avaliação em CAD/CAM, as técnicas T4 e T3 apresentaram maiores diferenças em relação ao modelo original de acordo com as imagens sobrepostas. Conclusões: Todas as técnicas estudadas apresentaram alterações dimensionais, em especial a técnica simultânea e a sem alívio, tanto nas medidas obtidas quanto na análise em CAD/CAM.


Objetives: To compare different impression techniques with addition silicone, by means of copy accuracy through manual measurements and overlaping in CAD/CAM. Material and methods: Four impressions of a same pilot model were carried out with silicone addition in different techniques: T1 ­ two steps with cut-back; T2 ­ two steps with PVC film relief; T3 ­ two steps without relief; and T4 ­ one step. The accuracy of the 4 different impression techniques was assessed by measuring 5 dimensions on stone casts poured from the impressions of the pilot model. Another analysis was carried out in CAD/CAM using the overlaping of the casts and the pilot model, in order to verify dimensional similarities and differences between them. The values obtained were submitted to ANOVA and Tukey test, for multiple comparisons (α=0.05). Results: According to the measures done, the technique that generated the greatest difference from the pilot model was T4, with no difference among the other techniques. In CAD/CAM analysis, techniques T4 and T3 presented more differences from the original model. Conclusions: All studied techniques presented dimensional changes, mainly the 1 step and the 2 step without relief, in both methods, measures and CAD/CAM analysis.

13.
Rev. bras. cir. plást ; 34(1): 120-126, jan.-mar. 2019.
Article in English, Portuguese | LILACS | ID: biblio-994565

ABSTRACT

Introdução: A cirurgia de mama, especialmente as associadas aos implantes de silicone, teve uma crescente popularização, tornando-se a cirurgia plástica mais realizada no mundo. Junto com esta proliferação, observa-se um aumento da preocupação com a segurança dos implantes mamários de silicone, pelas intercorrências relacionadas. Objetivo: Revisar métodos existentes para minimizar as complicações relacionadas com implante mamário de silicone, bem como as tecnologias existentes e tendências tecnológicas para implantes mamários de silicone. Métodos: Foi realizada revisão de artigos científicos relacionados com novas tecnologias e tendências para redução das complicações relacionadas com implantes mamários de silicone, bem como as patentes e fabricantes de implante de silicone mamário. Resultados: Identificamos inicialmente 78 referências, sendo reduzido para 40 para publicação, todos com linhas de pesquisas que buscam melhores resultados e redução das complicações relacionadas com implantes de silicone, seja esta cirurgia com objetivo estético ou reconstrutivo. Conclusão: A busca por um implante mamário que reduza as possíveis e frequentes complicações, principalmente a formação do biofilme, processos infecciosos e resposta imune, é o foco da maioria das pesquisas encontradas. Com o mesmo objetivo, porém surgindo mais recentemente como alternativas, existem as pesquisas para o uso de matriz dérmica acelular e a lipoenxertia, com boas expectativas.


Introduction: Breast surgery with silicone implants is gaining popularity and has become the most performed plastic surgery worldwide. However, there is increasing concern about the safety of silicone breast implants due to associated complications. Objective: To review existing technologies, technological trends, and existing methods to minimize complications related to silicone breast implants. Methods: We conducted a literature review of articles describing new technologies and trends to reduce complications related to silicone breast implants, along with information on patents and manufacturers of silicone breast implants. Results: We initially identified 78 articles, out of which 40 were shortlisted for publication . All articles had a common aim of obtaining better results and reducing complications related to silicone implants, either in aesthetic or reconstructive surgeries. Conclusion: The search for a breast implant that reduces possible and frequent complications, especially biofilm formation, infectious processes, and abnormal immune response, was the focus of most articles studied. Acellular dermal matrix and fat grafting have been reported in the literature as promising alternatives.


Subject(s)
Humans , Female , Middle Aged , Aged , Silicone Elastomers/adverse effects , Silicone Elastomers/standards , Breast Neoplasms/surgery , Mammaplasty/methods , Breast Implants/adverse effects , Breast Implants/standards , Plastic Surgery Procedures/methods , Plastic Surgery Procedures/trends
14.
Pesqui. bras. odontopediatria clín. integr ; 19(1): 3962, 01 Fevereiro 2019. ilus, tab
Article in English | LILACS, BBO | ID: biblio-997961

ABSTRACT

Objective: To evaluate the inclusion capacity and bactericidal efficiency of diallyl dimethyl ammonium chloride (PDADMAC) diluted in tetrahydrofuran (THF) upon inclusion in the medical grade silicone polymer structure. Material and Methods: It was diluted the PDADMAC in THF at the concentration of 4wt%. It was included in the silicon paste during its vulcanization process. The contact angle measurements were performed to evaluate whether the biocide inclusion into the silicon paste was successful. All samples were sterilized with gamma radiation at 25KGy-dosage prior to the microbiological tests. Microbiological testing strictly followed the Antibacterial products - Test for antibacterial activity and efficacy JIS Z 2801: 201010 and the used of specific bacteria, as Staphylococcus aureus ATCC 6538P and Escherichia coli ATCC 8739. Results: The results showed that PDADMAC, when dissolved in THF at 4wt%, displayed good incorporation in medical silicone and a broad-spectrum antibacterial response. The results of the tests using Escherichia coli ATCC 8739 and Staphylococcus aureus ATCC 6538P showed that the silicone with no biocide addition did not present antibacterial activity. In contrast, the experimental group plus 2 mL of PDADMAC would have an ideal antibacterial response. Conclusion: Medical grade silicone can be used as a material with antibacterial properties, since it has been able to keep PDADMAC compound attached to its structure, thus acquiring antimicrobial property.


Subject(s)
Silicone Elastomers/analysis , In Vitro Techniques/methods , Maxillofacial Prosthesis , Anti-Bacterial Agents/analysis , Silicone Elastomers , Brazil , Dental Materials , Methylenetetrahydrofolate Reductase (NADPH2)
15.
Article | IMSEAR | ID: sea-183593

ABSTRACT

Background: Facial defects can be acquired or congenital, but irrespective of etiology, any maxillofacial structure if damaged or missing will result in an unaesthetic and unappealing personality of individual. Orbital defects are very evident and effect the appearance and social front of the individual. Many modalities are available to rehabilitate the defect of an orbit but prosthetic rehabilitation with silicone prosthesis is a simple and effective approach. Retention is generally achieved by engaging available undercuts or using mechanical accessories or skin adhesives etc. This case report describes successful rehabilitation of right orbital defect using a non-surgical approach with room temperature vulcanized silicone and skin adhesives. Case Report: A 45 yr old male reported with, chief complaint of missing right orbit and unaesthetic appearance secondary to gunshot wound. Patient was not ready for any more surgical procedures or additional accessories and available retentive undercuts were minimal. Hence, conventional silicone prosthesis was made using stock eye shell and room temperature vulcanized silicone retained with skin adhesives. The approach was simple to a complex problem and gave reliable result in very limited time. Conclusion: With extensive orbital defect, rehabilitation is difficult and complex as retention is compromised and it is difficult to match the shade of the prosthesis.This case represents a simple and predictable approach to a case of exenterated right orbit with conventional roomtemperature vulcanized silicone and silicone skin adhesives.

16.
Article | IMSEAR | ID: sea-183531

ABSTRACT

Background: Facial defects can be acquired or congenital, but irrespective of etiology, any maxillofacial structure if damaged or missing will result in an unaesthetic and unappealing personality of individual. Orbital defects are very evident and effect the appearance and social front of the individual. Many modalities are available to rehabilitate the defect of an orbit but prosthetic rehabilitation with silicone prosthesis is a simple and effective approach. Retention is generally achieved by engaging available undercuts or using mechanical accessories or skin adhesives etc. This case report describes successful rehabilitation of right orbital defect using a non-surgical approach with room temperature vulcanized silicone and skin adhesives. Case Report: A 45 yr old male reported with, chief complaint of missing right orbit and unaesthetic appearance secondary to gunshot wound. Patient was not ready for any more surgical procedures or additional accessories and available retentive undercuts were minimal. Hence, conventional silicone prosthesis was made using stock eye shell and room temperature vulcanized silicone retained with skin adhesives. The approach was simple to a complex problem and gave reliable result in very limited time. Conclusion: With extensive orbital defect, rehabilitation is difficult and complex as retention is compromised and it is difficult to match the shade of the prosthesis.This case represents a simple and predictable approach to a case of exenterated right orbit with conventional roomtemperature vulcanized silicone and silicone skin adhesives.

17.
The Journal of Advanced Prosthodontics ; : 155-161, 2019.
Article in English | WPRIM | ID: wpr-761409

ABSTRACT

PURPOSE: Although dental impression disinfection is determinant to reduce the cross-infection risk, some studies have shown that, in real practice, the disinfection procedures vary considerably. Thus, the aim of this study was to evaluate the antimicrobial effectiveness and the impact on the dimensional stability of addition silicone' impressions of water wash and the most clinically used disinfection solutions: 3% hydrogen peroxide, commercial disinfectant MD520 (Durr) and 1% and 5.25% sodium hypochlorite. MATERIALS AND METHODS: For this investigation, dental impressions were taken on 16 volunteer dental students. The antimicrobial effectiveness of each procedure was evaluated by pour plate method. The dimensional stability was evaluated using a standardized stainless-steel model, according to ANSI/ADA nº19 specification. RESULTS: The study results showed that water wash does not alter the dimensional stability of addition silicone impressions but doesn't reduce the microbial load of the material (P>.05). On the other hand, addition silicone disinfection by immersion with 3% hydrogen peroxide, MD520 (Durr), or sodium hypochlorite at 1% and 5.25% does not alter the dimensional stability significantly but reduces > 99.9% of the microbial load of the impressions (P<.001). CONCLUSION: Addition silicone impressions should always be disinfected after water wash in order to reduce effectively the cross-infection risk. All disinfectants tested showed high antimicrobial efficiency without significant changes in three-dimensional shape of impressions. Hydrogen peroxide and sodium hypochlorite are of particular importance because are easily accessible in dental setting. The less explored hydrogen peroxide could be a valuable alternative for silicone impressions disinfection.


Subject(s)
Humans , Disinfectants , Disinfection , Hand , Hydrogen Peroxide , Immersion , Methods , Silicon , Silicone Elastomers , Silicones , Sodium Hypochlorite , Students, Dental , Volunteers , Water
18.
Rev. odontol. UNESP (Online) ; 48: e20190064, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1043186

ABSTRACT

Abstract Introduction Making accurate and dimensionally stable impressions to duplicate oral conditions and tooth morphology is an essential step of prosthetic dentistry for fabricating well-fitted indirect restorations and, consequently, ensure the longevity and success of the treatment. Several authors describe pros and cons of different impression techniques, although there is no unanimity among them about the best one. Objective This study evaluated casts' accuracy made by different impression techniques, trays and materials. Material and method 10 patients were selected and 20 impressions from teeth #13 to #16 were performed using single-step (SS) and two-step techniques, made with metal stock and customized acrylic resin partial trays, vinyl polysiloxane and condensation silicone rubbers. Type IV gypsum was used to pour the casts. Three photographs of each patient (baseline), as their respective gypsum casts, were taken, measured in their interested buccal surface area. Comparisons of area values among experimental groups and baseline were performed. Data showed adherence to normal curve, being submitted to 3-way ANOVA/Bonferroni test (α=.05). Result Technique produced significant differences (P=0.02). SS technique was more accurate than BUR one (P=0.003; 95=1.22 to 5.98), but both resulted in similar casts to PVC, MOV and NR techniques, which were similar to each other (P>0.05). Conclusion SS technique showed the closest absolute values to baseline.


Resumo Introdução Realizar moldagens precisas e dimensionalmente estáveis que dupliquem a condição oral é um passo essencial para a confecção de restaurações indiretas de qualidade, garantindo seu sucesso e longevidade. Diversos estudos tem demonstrado os prós e contras de diferentes técnicas de moldagem, mas nenhum consenso da melhor técnica ainda foi descrito. Objetivo Este estudo avaliou a exatidão de modelos de gesso confeccionados por diferentes técnicas de moldagem, moldeiras e materiais. Material e método 10 pacientes foram selecionados e 20 moldes dos dentes #13 até #16 foram realizados utilizando técnicas simultânea (SS) e de dois passos, realizados com moldeiras parciais metálicas e individuais de resina acrílica, silicones de adição e condensação. Gesso tipo IV foi usados para os vazamentos. Três fotografias de cada paciente (baseline), assim como dos seus respectivos modelos de gesso foram realizadas e sua área foi então mensurada, na porção vestibular. Comparações de valores de área entre os grupos experimentais e o baseline foram performadas. Os dados mostraram aderência a curva normal, sendo submetidos ao teste 3-way ANOVA/Bonferroni (α=.05). Resultado As técnicas produziram diferenças significativas (P=0.02).Técnica simultânea foi mais precisa que a BUR (P=0.0003; 95=1,22 a 5.98), mas ambas resultaram em modelos similares àqueles feitos por meio das técnicas de PVC, MOV e sem NR, que foram similares entre si (P>0.05). Conclusão Técnica simultânea demonstrou valores absolutos similares àqueles demonstrados pelo baseline.


Subject(s)
Humans , Adult , Middle Aged , Aged , Silicone Elastomers , Dental Impression Technique , Dental Impression Materials , Acrylic Resins
19.
HU rev ; 45(2): 156-164, 2019.
Article in Portuguese | LILACS | ID: biblio-1048781

ABSTRACT

Introdução: O envelhecimento da população aumenta a necessidade de reabilitação protética e o custo do atendimento odontológico. Para reabilitar com qualidade e baixo custo é necessário conhecer os materiais odontológicos desse processo, como os materiais de moldagem. O mais utilizado no Brasil é a silicona de condensação, que possui limitações. Porém, o fabricante modificou a fórmula com o intuito de melhorar a estabilidade dimensional. Objetivo: avaliar a estabilidade dimensional da silicona de condensação Speedex com a nova tecnologia DCP, em diferentes tempos de vazamento nas moldagens para prótese fixa. Material e métodos: Foi confeccionado um modelo padrão metálico com dois cilindros de mesmos diâmetros e mesma altura para simular uma prótese fixa. Foi elaborada uma moldeira metálica padronizada com retenções e guias de inserção. A partir dessa, outras quatro, em acrílico incolor, foram reproduzidas pelo alginato reversível. No total, foram realizadas 20 impressões, sendo 5 impressões por grupo. Os grupos foram vazados com o gesso tipo IV em diferentes tempos: grupo 1 (n=5): imediato; grupo 2 (n=5): 30 min; grupo 3 (n=5): 36h; grupo 4 (n=5): 72h. O modelo padrão e todos os modelos de gesso do grupo 1, 2, 3 e 4 foram medidos por dois pesquisadores de forma cega com auxílio de um paquímetro digital. Foram analisadas as distâncias externas e internas entre os pontos de referência dos cilindros. Os grupos foram comparados pelo teste t de Student, o nível de significância considerado foi p<0,05. Resultados: não se observou diferença estatística entre as medidas do pesquisador 1 e 2 (p>0,05). Não houveram diferenças entre os grupos 1 e 2 e 1 e 3; porém houve diferença significativa entre o 1 e 4. Conclusão: A silicona de condensação Speedex, não altera a estabilidade dimensional com o vazamento em até 36 horas.


Introduction: The aging of the population increases the need for prosthetic rehabilitation and the cost of dental care. To rehabilitate with quality and low cost is necessary to know the dental materials of this process, such as impression materials. The most used in Brazil is condensation silicon, which has limitations. However, the manufacturer modified the formula to improve dimensional stability. Objective: To evaluate the dimensional stability of Speedex condensation silicon with the new DCP technology at different casting times in fixed prosthesis moldings. Material and methods: A standard metal model with two cylinders of the same diameters and the same height was made to simulate a fixed prosthesis. A standard metal tray with drawers and insertion guides was developed. This metal tray was duplicated using reversible alginate. From this, four colorless acrylic trays were reproduced. In total, 20 impressions were made, with 5 impressions per group. The groups were cast with type IV gypsum at different times: group 1 (n=5): immediate; Group 2 (n=5): 30 min; group 3 (n=5): 36h; group 4 (n=5): 72h. The standard model and all gypsum models of groups 1, 2, 3 and 4 were measured by two researchers blindly using a digital caliper. The external and internal distances between the reference points of the cylinders were analyzed. The groups were compared by Student's t test, the significance level considered was p<0.05. Results: no statistically significant difference was found between researcher 1 and 2 by (p<0.05). There were no differences between groups 1 and 2 and 1 and 3; however, there was a significant difference between 1 and 4. Conclusion: Speedex condensing silicone does not change dimensional stability with leakage within 36 hours. Key-words: Dental Impression Materials, Dental Prosthesis, Silicone Elastomers. Submetido: 14/06/2019Aceito: 16/08/2019 Rebeca Vidal Capelupi1,2,Viviam Salvato de Souza1,2,Marcelo Tarcísio Martins1,Júlio Marcos Gouvêa Chagas1,Rogério Teodoro de Aquino3,Thalyta dos Reis Furlani Zouain-Ferreira1,Fabiana Aparecida Mayrink de Oliveira1,21Faculdade de Ciências Médicas e da Saúde de Juiz de Fora, Curso de Odontologia ­ Juiz de Fora, MG. 2Programa Institucional de Bolsas de Iniciação Científica (PIBIC) ­ FCMS/JF 2018.2 3Usinagem Mecânica Industrial, SENAI, Juiz de Fora, MG. Avaliação da estabilidade dimensional da silicona de condensação em diferentes tempos de vazamento em moldagens para prótese fixaEvaluation of the dimensional stability of the condensation silico-ne in different leakage times in moldings for fixed prosthesis * Fabiana de OliveiraAvenida Barão do Rio Branco, 1871/1105, CentroJuiz de Fora ­ MG CEP: 36013-020 8 fabsmay@hotmail.com


Subject(s)
Humans , Male , Female , Silicone Elastomers , Aging , Dental Prosthesis , Dental Impression Materials , Denturists , Mouth Rehabilitation
20.
Dental press j. orthod. (Impr.) ; 23(6): 42-47, Nov.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-975034

ABSTRACT

ABSTRACT Objective: This clinical study was conducted in order to evaluate force decay over time of latex and non-latex orthodontic intraoral elastics. Methods: Patients (n = 15) were evaluated using latex and non-latex elastics in the periods of : 0, 1, 3, 12 and 24 hours. The rubber bands were transferred to the testing machine (EMIC DL-500 MF), and force values were recorded after stretching the elastic to a length of 25mm. Paired t test was applied and analysis of variance (ANOVA) was used to evaluate the variation of force generated. LSD (Fisher's least significant difference) post-hoc test was thus employed. Results: As regards the initial forces (zero time), the values of force for non-latex elastic were slightly higher than for the latex elastic. In the subsequent times, the forces generated by the latex elastic showed higher values. Regarding the material degradation, at the end of 24 hours the highest percentage was observed for non-latex elastic. Conclusions: The latex elastics had a more stable behavior during the studied period, compared with non-latex.


RESUMO Objetivo: o objetivo deste estudo clínico foi avaliar e comparar o comportamento dos elásticos de látex e não látex quanto à perda de força ao longo do tempo. Método: os pacientes (n = 15) foram avaliados usando ambos os tipos de material (látex e não látex) em cada tempo: 0, 1, 3, 12 e 24 horas. Os elásticos foram transferidos para a máquina de ensaios mecânicos (EMIC DL-500 MF) e os valores de força foram registrados após a distensão dos elásticos a uma distância de 25 mm. Foi aplicado o teste t pareado, e a análise de variância (ANOVA) foi realizada para verificar a variação das forças geradas em todos os tempos estudados. Em seguida, o teste post-hoc LSD (Fisher's least significant difference) foi aplicado. Resultados: quanto às forças iniciais (tempo zero), os valores de força dos elásticos não látex foram ligeiramente maiores do que dos elásticos de látex. Nos tempos subsequentes, as forças geradas pelos elásticos de látex apresentaram valores superiores às geradas pelos elásticos não látex. Em relação à degradação do material, ao fim do período de 24 horas, o maior percentual foi observado pelos elásticos não látex. Conclusões: os elásticos de látex apresentaram comportamento mais estável durante o período de estudo, em comparação aos não látex.


Subject(s)
Humans , Adult , Young Adult , Orthodontic Appliances , Rubber/chemistry , Dental Materials/chemistry , Latex/chemistry , Silicone Elastomers/chemistry , Stress, Mechanical , Tensile Strength , Materials Testing , Analysis of Variance , Orthodontic Appliance Design , Dental Stress Analysis/methods , Elasticity , Mechanical Phenomena
SELECTION OF CITATIONS
SEARCH DETAIL